loader
t

Control Transformer

At Denki Seigyo, we design and manufacture high-quality custom transformers tailored to your exact specifications. Our range includes control, isolation, step-down, and distribution transformers from 50 VA to 500 kVA, built using premium CRGO cores and high-grade copper windings. Every unit is engineered for maximum efficiency, low losses, and superior reliability under diverse industrial conditions.
Choose Denki Seigyo for precision-built, durable, and fully customizable transformer solutions that power your automation and electrical systems with confidence.

 

 

For more details. Denki_Seigyo_500VA_Transformer_Datasheet

Category:
Control Transformer

Technical Specification for Transformer

1. General Information

Parameter Specification
Type Single Phase, Double Wound, Air / Oil Cooled (as required)
Application Step-down / Control / Isolation Transformer
Rated Capacity 500 VA and Customizable as per requirement.
Frequency 50 Hz ±3%
Phase Single Phase
Duty Continuous (S1 Duty)

2. Electrical Parameters

Parameter Specification
Primary Voltage 230 V AC ±10% (customizable e.g., 415V)
Secondary Voltage 110 V / 24 V / 12 V AC (as per design)
Connection Type Two winding, Delta / Star as applicable
Tapping Range ±5% (if required)
Power Factor 0.8 lag (typical for rating)
Impedance Voltage 4–6% (typical)
Efficiency ≥ 95% at full load
Regulation Within ±5% from no-load to full-load

3. Constructional Features

Component Specification
Core Material Cold Rolled Grain Oriented (CRGO) Silicon Steel Lamination, M4 or better
Core Type Shell / Core type, low-loss laminated stack
Winding Material Super Enamelled Copper (EC Grade)
Winding Insulation Class ‘B’ (130°C) / Class ‘F’ (155°C) as specified
Terminals Brass studs / terminal blocks / flying leads
Insulation Resistance (IR) ≥ 100 MΩ at 500 V DC (megger test)
Dielectric Strength 2.5 kV RMS for 1 minute between windings and earth
Cooling Type AN (Air Natural) / ONAN (Oil Natural Air Natural)
Mounting Type Floor / Wall / Panel mounting
Enclosure Powder-coated MS box, IP23 / IP44 (as required)

4. Temperature & Environment

Parameter Specification
Ambient Temperature Up to 45°C
Maximum Temperature Rise 55°C (oil-cooled) / 75°C (air-cooled)
Relative Humidity Up to 95% (non-condensing)
Altitude Up to 1000 m above MSL

5. Testing and Standards

Test Requirement
Type Tests As per IS 2026 / IS 11171 / IEC 60076
Routine Tests 1. Ratio Test
2. Polarity and Phase test
3. No-load loss and current
4. Load loss and impedance voltage
5. Insulation resistance
6. High voltage (HV) test
Applicable Standards IS: 2026 (Power Transformers)
IS: 11171 (Dry-Type)
IEC 60076

6. Accessories (if applicable)

  • Lifting lugs

  • Earthing terminals

  • Nameplate (engraved stainless steel)

  • Oil level gauge (for oil-cooled)

  • Drain plug and filling cap

  • Breather (for oil-cooled type)


8. Guarantee/Warranty

  • 12 month from the date of installation or 18 month from the date of manufacturing whichever earlier.