TRIAC POWER REGULATOR
Product Overview
The Denki Seigyo DTR Series solid state voltage regulators are compact, high-performance thyristor (Triac/SCR) regulators designed for AC load control in industrial automation and power management systems.
Available in single-phase (DTR1 Series) and three-phase (DTR3 Series) variants, these regulators offer precise phase-angle control, proportional voltage regulation, and isolated control signal interfaces.
Each model is engineered for stable operation, long life, and smooth analog signal response (0–10V / 4–20mA control) in resistive or inductive load applications.
Key Features
-
Single and three-phase Triac-based voltage regulation
-
Phase-angle and zero-cross control options
-
High current capacity (up to 100A)
-
Analog control input (0–10V / 4–20mA)
-
Isolated control and power sections for safety
-
Built-in LED indicators for operation and fault display
-
Fan-cooled and heat sink integrated options
-
Compact, panel-mount design with screw terminals
-
CE and RoHS compliant industrial-grade build

Technical Specifications (General)
| Parameter | Specification |
|---|---|
| Control Signal Input | 0–10VDC / 4–20mA (Isolated) |
| Control Mode | Phase-angle control / Burst-fire control |
| Load Voltage Range | 85–265VAC (Single Phase) / 320–480VAC (Three Phase) |
| Output Current Range | 25A / 40A / 60A / 80A / 100A |
| Frequency Range | 47–63Hz |
| Triggering Device | Triac / SCR pair |
| Cooling Method | Natural convection or forced air cooling |
| Protection Features | Overheat, short-circuit, input surge protection |
| Indication | LED for Power, Fault, and Signal |
| Mounting Type | Panel Mount with M4 screw holes |
| Operating Temperature | −20°C to +80°C |
| Storage Temperature | −30°C to +100°C |
| Insulation Resistance | ≥100MΩ (500VDC) |
| Dielectric Strength | 2500VAC between input/output for 1 min |
| Compliance | CE, RoHS |
| Model | Phase Type | Control Type | Input Control Signal | Rated Output Current | Load Voltage | Communication / Interface | Features |
|---|---|---|---|---|---|---|---|
| DTR1-060-VI | Single Phase | Triac Regulator | 0–10VDC / 4–20mA | 60A | 220VAC | Analog | Compact, single-phase phase-angle control |
| DTR1-060-VI | Single Phase | Triac Regulator | 0–10VDC / 4–20mA | 60A | 220VAC | Analog | High-capacity version with extended heat sink |
| DTR1-100-VI | Single Phase | Triac Regulator | 0–10VDC / 4–20mA | 100A | 220VAC | Analog | Heavy-duty load control for heaters/motors |
| DTR3-080-VI-C | Three Phase | Triac Regulator | 0–10VDC / 4–20mA | 80A | 380VAC | RS-485 (MODBUS RTU) | Digital communication and multi-phase sync control |
| DTR3-100-VI-C | Three Phase | Triac Regulator | 0–10VDC / 4–20mA | 10A | 380VAC | RS-485 (MODBUS RTU) | Analog + communication control (digital setpoint input) |
| DTR3-200-VI-C | Three Phase | Triac Regulator | 0–10VDC / 4–20mA | 200A | 380VAC | RS-485 / MODBUS RTU | High-capacity intelligent triac regulator with digital feedback |
Applications
-
Electric heating control (Ovens, Furnaces, Heaters)
-
Industrial automation systems
-
Power management and voltage regulation
-
Motor speed control (AC motors, fans)
-
Lighting dimming and energy-saving control
-
Process temperature and load balancing systems
Performance & Functional Characteristics
-
Switching Frequency: Typically full‑wave line frequency (50/60 Hz) with triac gating every half‐cycle. The regulator adjusts conduction angle to regulate voltage.
-
Minimum Load Requirement: Some minimum current (e.g., >5 A) may be needed for stable operation (especially inductive loads).
-
Response Time: Rapid change in output when control input changes (milliseconds range) enabling tight process control.
-
Efficiency & Heat Dissipation: Minimal internal losses but triac will dissipate heat; good heatsinking required to maintain junction temperature <125 °C.
-
EMI Considerations: Because phase‑angle switching creates harmonics, noise suppression (e.g., R‑C snubber, mains filter) recommended.
-
Control Input Accuracy: High linearity between control signal (0–10 V) and output voltage (e.g., 0–100% of load power).
-
Indicator / Status: Possibly built‑in LED indicators for power ON, fault, current limit (verify actual features).
Certifications & Compliance
-
CE marked (for European versions) – conformity with EMC and Low Voltage Directive.
-
RoHS compliant (lead‐free components) (check variant).
-
Designed in accordance with IEC 60947 series for power switching devices (verify).
-
For use within industrial control panels conforming to local safety standards (e.g., IEC or IS in India).
Installation & Maintenance Notes
-
Mount the regulator vertically on flat metal surface; ensure proper air clearance to allow convection.
-
Provide an adequately dimensioned heatsink or fan if ambient >40 °C or if current continuously near maximum.
-
Use correct size cables and terminations for the 60 A rating; ensure adequate earthing.
-
Avoid mounting near high vibration, corrosive fumes, or extreme ambient conditions unless variant rated for that.
-
Inspect periodically: check terminal torque, cooling path free of dust, and verify indicator LEDs.
-
Have spare fuses or over‑current protection devices appropriate for the load and regulator rating.
Typical Applications
-
Thermal process control: heaters in ovens, furnaces, laminators.
-
Motor speed or power modulation (when used with resistive or lightly inductive loads).
-
Lighting control in industrial/high‑bay systems (with compatible load).
-
Any application demanding smooth AC power regulation and minimal flicker or step change in output.